Property: 1968 residential single-family, mid-century subdivision Pelham NH
Owner: G.L. (property owner alias)
Scope: Aging Liberty Utilities gas furnace and central AC replaced with mid-tier Bosch IDS 2.0 variable-capacity heat pump using existing ductwork; complete fossil-fuel elimination through Liberty Utilities gas service disconnection coordination
Timeline: Diagnostic and design 3 weeks (including Liberty Utilities disconnection coordination), installation 4 days
Investment: $22,600 installed, $2,000 NH Saves heat pump rebate, $2,000 IRA 25C federal tax credit, net $18,600
G.L. owns a 1968 residential single-family property in one of Pelham NH’s mid-century subdivision areas near Route 38 corridor. Pelham NH mid-century subdivision development includes several coordinated 1960s-70s subdivision areas near Route 38 and other primary road corridors where Liberty Utilities gas distribution infrastructure was extended during subdivision development.
The Liberty Utilities gas coverage areas in Pelham NH provide important context contrast to the rural propane retention areas covered in prior Pelham NH case studies (Beaver Lake waterfront, Little Island Pond seasonal cottage, Route 38 corridor rural propane). Pelham NH’s approximately 30-50% of properties with Liberty Utilities gas coverage are concentrated in the developed subdivision areas near primary roads; the remaining 50-70% of properties with propane retention are more consistently distributed across the town’s rural residential areas.
G.L.’s subdivision area configuration: mid-century 1960s-70s subdivision development with typical residential properties of the era — 1,800-2,400 sq ft single-family construction on 0.3-0.6 acre lots, standard 8-foot ceilings, coordinated street layout with municipal water/sewer/gas infrastructure, forced-air gas heating configurations original to subdivision development or from subsequent replacement cycles.
G.L.’s property configuration: approximately 2,100 sq ft two-story residential, forced-air Liberty Utilities gas furnace replaced approximately 18 years ago serving ducted distribution throughout, matching central AC installed with the gas furnace, gas water heater in basement mechanical space (G.L. plans coordinated future replacement with heat pump water heater for complete fossil-fuel elimination at time of future upgrade cycle).
G.L. requested Rivic assess replacement options with priorities: (1) coordinated replacement of the aging 18-year Liberty Utilities gas furnace and central AC given both approaching end-of-life range, (2) fossil-fuel elimination through heat pump conversion for NH Saves rebate opportunity, (3) Liberty Utilities gas service coordination — either complete disconnection for full fossil-fuel elimination or partial retention for retained gas water heater, (4) mid-tier equipment specification matching mid-century subdivision area market context.
Marcus Devlin conducted the initial diagnostic assessment given his gas equipment expertise relevant to Liberty Utilities coordination scope. Kathleen Brennan initiated Liberty Utilities gas service coordination in parallel.
Key findings: (1) 18-year Liberty Utilities gas furnace with declining efficiency (approximately 76-82% effective from 90% AFUE nameplate), heat exchanger inspection showed corrosion but no cracks yet, (2) 18-year central AC with typical refrigerant charge decline, (3) existing ductwork from 18-year installation scope in acceptable condition suitable for heat pump conversion, (4) 200A Eversource NH electric service adequate for heat pump installation with capacity margin, (5) Liberty Utilities gas service disconnection scope: gas water heater retained requires continued Liberty Utilities gas service (G.L. plans separate replacement in future upgrade cycle, at which point complete Liberty Utilities disconnection would apply); current installation scope maintains reduced-demand Liberty Utilities service for water heater only.
ACCA Manual J load calculation determined property heating load at 4°F winter design of approximately 48,000 BTU/hr and cooling load at 88°F summer design of approximately 34,000 BTU/hr.
Rivic recommended Bosch IDS 2.0 mid-tier variable-capacity heat pump 4-ton nominal capacity with existing ductwork utilization. Equipment specification: (1) Bosch IDS 2.0 inverter-driven variable-capacity outdoor unit, (2) Bosch matched indoor air handler with variable-speed ECM blower, (3) Bosch standard programmable thermostat, (4) 5-year Bosch parts warranty + 10-year compressor warranty.
Existing ductwork utilization: minor duct sealing improvements at accessible joints; supply and return grille inspection confirmed adequate condition from the 18-year installation scope; variable-speed ECM blower matched to Bosch IDS 2.0 variable-capacity operation.
Gas furnace decommissioning: 18-year Liberty Utilities gas furnace removed with proper procedures; gas piping capped at previous furnace location. Liberty Utilities meter and service line retained for water heater; G.L.’s future water heater replacement (planned 2-3 years out based on current water heater condition) will trigger complete Liberty Utilities service disconnection at that time.
Marcus’s MA Journeyman Gas Fitter licensure appropriate for the gas furnace decommissioning even though the property is in NH (NH does not have state gas fitter licensure requirement; MA licensure accepted for NH installations).
Pelham NH’s Liberty Utilities gas coverage in the developed subdivision areas is a distinctive characteristic of the town’s HVAC scope that contrasts with the substantial propane retention pattern in more rural areas. Some observations across Rivic’s Pelham NH service experience:
Liberty Utilities partial retention coordination for G.L.’s installation follows the same protocol as the Policy Street Salem NH case study:
Installation completed over 4 days including outdoor Bosch IDS 2.0 placement, indoor Bosch air handler installation, ductwork sealing improvements, refrigerant charging, gas furnace decommissioning, and thermostat programming coordination with G.L. Post-installation first-year operational verification: heat pump operated reliably through the first winter including cold-snap periods with outdoor temperatures reaching 3°F to 7°F range typical of Pelham NH climate.
Post-installation first-year utility monitoring: total electric operating cost approximately $1,380 for combined heating and cooling. Previous year utility costs: Liberty Utilities gas heating approximately $1,240 (18-year furnace declined efficiency), electric cooling approximately $580 (18-year AC declining efficiency), combined approximately $1,820/year. Annual operating cost reduction approximately $440/year — modest reduction reflecting G.L.’s moderate property scope and the mid-tier equipment selection. Continued Liberty Utilities gas water heater operating cost approximately $260/year (reduced from previous approximately $420/year with prior delivery scheduling reflecting combined furnace + water heater load).
Pelham NH mid-century subdivision area and other Pelham NH developed area residential HVAC service including 18+ year Liberty Utilities gas furnace and central AC replacement with mid-tier or premium cold-climate variable-capacity heat pump, existing ductwork utilization with ECM blower upgrade, Liberty Utilities gas service coordination (complete disconnection for full fossil-fuel elimination or partial retention for retained gas appliances), NH Saves rebate coordination, IRA 25C federal tax credit coordination, and manufacturer warranty administration all route through our 225 Broadway #306 office in downtown Methuen. This case study represents a specific installation completed for G.L.; individual property assessments determine equipment specification and installation scope.